Protocol Type: sterility
Protocol Name: NCL Method STE-2.1: Detection of Microbial Contamination Using Millipore Sampler Devices
Protocol Abbreviation: STE-2.1
Protocol Version: 3
DOI: http://dx.doi.org/10.17917/DVJF-SS25
Protocol File: 20240409_12-34-51-885_NCL_Method_STE-2.1.pdf
File Title: STE-2.1
Description: This protocol describes a procedure for quantitative determination of microbial contamination in a nanoparticle preparation. The protocol includes tests for yeast, mold and bacteria using Millipore Sampler devices [1]. The intended purpose of this assay is to avoid introduction of microbial contamination into in vitro cell cultures and in vivo animal studies utilizing the test-nanomaterial, as microbial contamination will confound the results of these tests. This assay is not intended to certify the material as sterile.
Resource Type: Protocol
Data Access: https://general.datacommons.cancer.gov/#/data