Attribute |
Public IVL<PQ> singleCollimationWidth
|
Details:
Alias: |
|
Initial: |
|
Stereotype: |
|
Ordered: |
|
Range: |
Range:0 to 1 |
Transient: |
False |
Derived: |
False |
IsID: |
False |
Map:DICOM=CT Acquisition Details Macro - CT Acquisition Details Sequence > Single Collimation Width (0018,9306) Map:DICOM=Performed CT Acquisition Module - Acquisition Protocol Element Sequence (0018,9920) > Single Collimation Width (0018,9306)
Notes:
|
DEFINITION:<br/>The width of a single row of acquired data.<br/><br/>EXAMPLE(S):<br/><br/>OTHER NAME(S):<br/><br/>NOTE(S):<br/>The units are of linear distince, e.g. mm.<br/>
|
|
Public IVL<PQ> totalCollimationWidth
|
Details:
Alias: |
|
Initial: |
|
Stereotype: |
|
Ordered: |
|
Range: |
Range:0 to 1 |
Transient: |
False |
Derived: |
False |
IsID: |
False |
Map:DICOM=CT Acquisition Details Macro - CT Acquisition Details Sequence > Total Collimation Width (0018,9307) Map:DICOM=Performed CT Acquisition Module - Acquisition Protocol Element Sequence (0018,9920) > Total Collimation Width (0018,9307)
Notes:
|
DEFINITION:<br/>The width of the total collimation over the area of active x-ray detection.<br/><br/>EXAMPLE(S):<br/><br/>OTHER NAME(S):<br/><br/>NOTE(S):<br/>The units are of linear distince, e.g. mm.<br/>
|
|
Public IVL<PQ> gantryDetectorTilt
|
Details:
Alias: |
|
Initial: |
|
Stereotype: |
|
Ordered: |
|
Range: |
Range:0 to 1 |
Transient: |
False |
Derived: |
False |
IsID: |
False |
Map:DICOM=CT Acquisition Details Macro - CT Acquisition Details Sequence > Gantry/Detector Tilt (0018,1120) Map:DICOM=Performed CT Acquisition Module - Acquisition Protocol Element Sequence (0018,9920) > Gantry/Detector Tilt (0018,1120)
Notes:
|
DEFINITION:<br/>Nominal angle of tilt in degrees of the scanning gantry. <br/><br/>EXAMPLE(S):<br/><br/>OTHER NAME(S):<br/><br/>NOTE(S):<br/>The units are of plane angle , e.g. degrees. Zero degrees means the gantry is not tilted, negative degrees are when the top of the gantry is tilted away from where the table enters the gantry.<br/>
|
|
Public IVL<PQ> tableSpeed
|
Details:
Alias: |
|
Initial: |
|
Stereotype: |
|
Ordered: |
|
Range: |
Range:0 to 1 |
Transient: |
False |
Derived: |
False |
IsID: |
False |
Map:DICOM=Performed CT Acquisition Module - Acquisition Protocol Element Sequence (0018,9920) > Table Speed (0018,9309) Map:DICOM=CT Table Dynamics Macro - CT Table Dynamics Sequence > Table Speed (0018,9309)
Notes:
|
DEFINITION:<br/>The distance that the table moves per unit of time during the gathering of data.<br/><br/>EXAMPLE(S):<br/><br/>OTHER NAME(S):<br/><br/>NOTE(S):<br/>The units are of linear distance divided by time.<br/>
|
|
Public IVL<PQ> spiralPitchFactor
|
Details:
Alias: |
|
Initial: |
|
Stereotype: |
|
Ordered: |
|
Range: |
Range:0 to 1 |
Transient: |
False |
Derived: |
False |
IsID: |
False |
Map:DICOM=CT Table Dynamics Macro - CT Table Dynamics Sequence > Spiral Pitch Factor (0018,9311) Map:DICOM=Performed CT Acquisition Module - Acquisition Protocol Element Sequence (0018,9920) > Spiral Pitch Factor (0018,9311)
Notes:
|
DEFINITION:<br/>Ratio of the distance that the table moves during a complete revolution of the source around the gantry orbit, to the width of the total collimation over the area of active x-ray detection. <br/><br/>EXAMPLE(S):<br/><br/>OTHER NAME(S):<br/><br/>NOTE(S):<br/>The units are of unity.<br/>
|
|
Public IVL<PQ> ctdiVol
|
Details:
Alias: |
|
Initial: |
|
Stereotype: |
|
Ordered: |
|
Range: |
Range:0 to 1 |
Transient: |
False |
Derived: |
False |
IsID: |
False |
Map:DICOM=CT Acquisition Details Macro - CT Exposure Sequence > CTDIvol (0018,9345) Map:DICOM=CT Exposure Macro - CT Exposure Sequence > CTDIvol (0018,9345) Map:DICOM=Performed CT Acquisition Module - Acquisition Protocol Element Sequence (0018,9920) > CTDIvol (0018,9345)
Notes:
|
DEFINITION:<br/>The average dose over the total volume scanned for the selected CT conditions of operation (calculated according to IEC 60601-2-44, Ed.2.1 (Clause 29.1.103.4)). <br/><br/>EXAMPLE(S):<br/><br/>OTHER NAME(S):<br/>Computed Tomography Dose Index (CTDI) Volume<br/><br/>NOTE(S):<br/>The units are energy dose, e.g. mGy.<br/>
|
|
Public CD ctdiPhantomTypeCode
|
Details:
Alias: |
|
Initial: |
|
Stereotype: |
|
Ordered: |
|
Range: |
Range:0 to 1 |
Transient: |
False |
Derived: |
False |
IsID: |
False |
Map:DICOM=CT Exposure Macro - CT Exposure Sequence > CTDI Phantom Type Code Sequence (0018,9346) Map:DICOM=Performed CT Acquisition Module - Acquisition Protocol Element Sequence (0018,9920) > CTDI Phantom Type Code Sequence (0018,9346)
Notes:
|
DEFINITION:<br/>The type of phantom to use for CTDI measurement according to IEC 60601-2-44.<br/><br/>EXAMPLE(S):<br/>(113690, DCM, "IEC Head Dosimetry Phantom")<br/>(113691, DCM, "IEC Body Dosimetry Phantom")<br/><br/>OTHER NAME(S):<br/>Computed Tomography Dose Index (CTDI) Phantom Type Code<br/><br/>NOTE(S):<br/>
|
|
Public IVL<PQ> kVp
|
Details:
Alias: |
|
Initial: |
|
Stereotype: |
|
Ordered: |
|
Range: |
Range:0 to 1 |
Transient: |
False |
Derived: |
False |
IsID: |
False |
Map:DICOM=CT XRay Details Sequence Macro - CT X-Ray Details Sequence > KVP (0018,0060) Map:DICOM=Performed CT Acquisition Module - Acquisition Protocol Element Sequence (0018,9920) > CT X-Ray Details Sequence (0018,9325) > KVP (0018,0060)
Notes:
|
DEFINITION:<br/>Peak kilovoltage output of the x-ray generator.<br/><br/>EXAMPLE(S):<br/>140 kv<br/><br/>OTHER NAME(S):<br/>KVP (0018,0060)<br/><br/>NOTE(S):<br/>The units are of electrical potential.<br/>
|
|
Public DSET<CD> exposureModulationTypeCode
|
Details:
Alias: |
|
Initial: |
|
Stereotype: |
|
Ordered: |
|
Range: |
Range:0 to * |
Transient: |
False |
Derived: |
False |
IsID: |
False |
Map:DICOM=CT Exposure Macro - CT Exposure Sequence > Exposure Modulation Type (0018,9323) Map:DICOM=Performed CT Acquisition Module - Acquisition Protocol Element Sequence (0018,9920) > CT X-Ray Details Sequence (0018,9325) > Exposure Modulation Type (0018,9323)
Notes:
|
DEFINITION:<br/>The manner in which tube current is varied in order to limit the dose.<br/><br/>EXAMPLE(S):<br/>NONE<br/>ANGULAR = current is modulated over different tube angles<br/>LONGITUDINAL = current is modulated along the axis of the table<br/>ECG_BASED = current is modulated based on the cardiac phase<br/>ORGAN_BASED = current is modulated based on the organs in the field of view<br/><br/>OTHER NAME(S):<br/>Exposure Modulation Type (0018,9323)<br/><br/>NOTE(S):<br/>
|
|