| Attribute | 
		
						
				
					Public CD   echoPulseSequenceCategoryCode
				 | 
			
			
														
					 Details:
					
					
						
							| Alias: | 
							 | 
						 
						
							| Initial: | 
							 | 
						 
						
							| Stereotype:  | 
							 | 
						 
						
							| Ordered:  | 
							 | 
						 
						
							| Range:  | 
							 | 
						 
						
							| Transient:  | 
							False | 
						 
						
							| Derived:  | 
							False | 
						 
							
							| IsID:  | 
						False | 
						 
					 
					
					Map:DICOM=MR Pulse Sequence Module - Echo Pulse Sequence (0018,9008) 
						
	
		| 
			Notes:  
		 | 
		
			DEFINITION:<br/>A coded value specifying an echo category of pulse sequences.<br/><br/>EXAMPLE(S):<br/>SPIN, GRADIENT, BOTH<br/><br/>OTHER NAME(S):<br/><br/>NOTE(S):<br/>
		 | 
	 
  
						
				 | 
			
			
				
					Public IVL<PQ>   diffusionBValue
				 | 
			
			
														
					 Details:
					
					
						
							| Alias: | 
							 | 
						 
						
							| Initial: | 
							 | 
						 
						
							| Stereotype:  | 
							 | 
						 
						
							| Ordered:  | 
							 | 
						 
						
							| Range:  | 
							 | 
						 
						
							| Transient:  | 
							False | 
						 
						
							| Derived:  | 
							False | 
						 
							
							| IsID:  | 
						False | 
						 
					 
					
					Map:DICOM=MR Diffusion Macro - MR Diffusion Sequence > Diffusion b-value (0018,9087) 
						
	
		| 
			Notes:  
		 | 
		
			DEFINITION:<br/>The factor by which the acquisition is sensitized to the Brownian motion of water molecules.<br/><br/>EXAMPLE(S):<br/><br/>OTHER NAME(S):<br/>diffusion sensitization factor<br/><br/>NOTE(S):<br/>The units are of time/area, e.g. s/mm2.<br/>
		 | 
	 
  
						
				 | 
			
			
				
					Public CD   diffusionDirectionalityCode
				 | 
			
			
														
					 Details:
					
					
						
							| Alias: | 
							 | 
						 
						
							| Initial: | 
							 | 
						 
						
							| Stereotype:  | 
							 | 
						 
						
							| Ordered:  | 
							 | 
						 
						
							| Range:  | 
							 | 
						 
						
							| Transient:  | 
							False | 
						 
						
							| Derived:  | 
							False | 
						 
							
							| IsID:  | 
						False | 
						 
					 
					
					Map:DICOM=MR Diffusion Macro - MR Diffusion Sequence > Diffusion Directionality (0018,9075) 
						
	
		| 
			Notes:  
		 | 
		
			DEFINITION:<br/>A coded value specifying whether diffusion conditions for the frame are directional, or isotropic with respect to direction.. <br/><br/>EXAMPLE(S):<br/>DIRECTIONAL, BMATRIX, ISOTROPIC, NONE<br/><br/>OTHER NAME(S):<br/><br/>NOTE(S):<br/>
		 | 
	 
  
						
				 | 
			
			
				
					Public PQ   magneticFieldStrength
				 | 
			
			
														
					 Details:
					
					
						
							| Alias: | 
							 | 
						 
						
							| Initial: | 
							 | 
						 
						
							| Stereotype:  | 
							 | 
						 
						
							| Ordered:  | 
							 | 
						 
						
							| Range:  | 
							 | 
						 
						
							| Transient:  | 
							False | 
						 
						
							| Derived:  | 
							False | 
						 
							
							| IsID:  | 
						False | 
						 
					 
					
					Map:DICOM=MR Image and Spectroscopy Instance Macro - Magnetic Field Strength (0018,0087) 
						
	
		| 
			Notes:  
		 | 
		
			DEFINITION:<br/>A vector quantity indicating the ability of a magnetic field to exert a force on moving electric charges. [The American Heritage® Science Dictionary]<br/><br/>EXAMPLE(S):<br/><br/>OTHER NAME(S):<br/><br/>NOTE(S):<br/>The units are of magnetic flux density, e.g. tesla.<br/>
		 | 
	 
  
						
				 | 
			
			
				
					Public CD   resonantNucleusCode
				 | 
			
			
														
					 Details:
					
					
						
							| Alias: | 
							 | 
						 
						
							| Initial: | 
							 | 
						 
						
							| Stereotype:  | 
							 | 
						 
						
							| Ordered:  | 
							 | 
						 
						
							| Range:  | 
							 | 
						 
						
							| Transient:  | 
							False | 
						 
						
							| Derived:  | 
							False | 
						 
							
							| IsID:  | 
						False | 
						 
					 
					
					Map:DICOM=MR Image and Spectroscopy Instance Macro - Resonant Nucleus (0018,9100) 
						
	
		| 
			Notes:  
		 | 
		
			DEFINITION:<br/>A coded value specifying the atomic nucleus that is the target of the acquisition.<br/><br/>EXAMPLE(S):<br/>1H, 3HE, 7LI, 13C, 19F, 23NA, 31P, 129XE<br/><br/>OTHER NAME(S):<br/><br/>NOTE(S):<br/>
		 | 
	 
  
						
				 | 
			
			
				
					Public CD   acquisitionContrastCode
				 | 
			
			
														
					 Details:
					
					
						
							| Alias: | 
							 | 
						 
						
							| Initial: | 
							 | 
						 
						
							| Stereotype:  | 
							 | 
						 
						
							| Ordered:  | 
							 | 
						 
						
							| Range:  | 
							 | 
						 
						
							| Transient:  | 
							False | 
						 
						
							| Derived:  | 
							False | 
						 
							
							| IsID:  | 
						False | 
						 
					 
					
					Map:DICOM=MR Image Description Macro - Acquisition Contrast (0008,9209) 
						
	
		| 
			Notes:  
		 | 
		
			DEFINITION:<br/>A coded value specifying the inherent (as opposed to exogenous)  contrast in the acquisition.<br/><br/>EXAMPLE(S):<br/>DIFFUSION<br/>FLOW_ENCODED - Flow Encoded contrast<br/>FLUID_ATTENUATED - Fluid Attenuated T2 weighted contrast<br/>PERFUSION - Perfusion weighted contrast<br/>PROTON_DENSITY - Proton Density weighted contrast<br/>STIR - Short Tau Inversion Recovery<br/>TAGGING - Superposition of thin saturation bands onto image<br/>T1 - T1 weighted contrast<br/>T2 - T2 weighted contrast<br/>T2_STAR - T2* weighted contrast<br/>TOF - Time Of Flight weighted contrast<br/><br/>OTHER NAME(S):<br/>inherent contrast<br/><br/>NOTE(S):<br/>
		 | 
	 
  
						
				 | 
			
			
				
					Public BL   inversionRecoveryIndicator
				 | 
			
			
														
					 Details:
					
					
						
							| Alias: | 
							 | 
						 
						
							| Initial: | 
							 | 
						 
						
							| Stereotype:  | 
							 | 
						 
						
							| Ordered:  | 
							 | 
						 
						
							| Range:  | 
							 | 
						 
						
							| Transient:  | 
							False | 
						 
						
							| Derived:  | 
							False | 
						 
							
							| IsID:  | 
						False | 
						 
					 
					
					Map:DICOM=MR Modifier Macro - MR Modifier Sequence > Inversion Recovery (0018,9009) 
						
	
		| 
			Notes:  
		 | 
		
			DEFINITION:<br/>Specifies whether an inversion recovery preparatory sequence is used in the acquisition.<br/><br/>EXAMPLE(S):<br/><br/>OTHER NAME(S):<br/><br/>NOTE(S):<br/>
		 | 
	 
  
						
				 | 
			
			
				
					Public ST   pulseSequenceName
				 | 
			
			
														
					 Details:
					
					
						
							| Alias: | 
							 | 
						 
						
							| Initial: | 
							 | 
						 
						
							| Stereotype:  | 
							 | 
						 
						
							| Ordered:  | 
							 | 
						 
						
							| Range:  | 
							 | 
						 
						
							| Transient:  | 
							False | 
						 
						
							| Derived:  | 
							False | 
						 
							
							| IsID:  | 
						False | 
						 
					 
					
					Map:DICOM=MR Pulse Sequence Module - Pulse Sequence Name (0018,9005) 
						
	
		| 
			Notes:  
		 | 
		
			DEFINITION:<br/>Name of the pulse sequence that is used for the acquisition.<br/><br/>EXAMPLE(S):<br/><br/>OTHER NAME(S):<br/><br/>NOTE(S):<br/>This is usually a vendor-specific name. <br/>
		 | 
	 
  
						
				 | 
			
			
				
					Public BL   multipleSpinEchoIndicator
				 | 
			
			
														
					 Details:
					
					
						
							| Alias: | 
							 | 
						 
						
							| Initial: | 
							 | 
						 
						
							| Stereotype:  | 
							 | 
						 
						
							| Ordered:  | 
							 | 
						 
						
							| Range:  | 
							 | 
						 
						
							| Transient:  | 
							False | 
						 
						
							| Derived:  | 
							False | 
						 
							
							| IsID:  | 
						False | 
						 
					 
					
					Map:DICOM=MR Pulse Sequence Module - Multiple Spin Echo (0018,9011) 
						
	
		| 
			Notes:  
		 | 
		
			DEFINITION:<br/>Specifies whether different lines in k-space are collected for a single frame.<br/><br/>EXAMPLE(S):<br/><br/>OTHER NAME(S):<br/><br/>NOTE(S):<br/>
		 | 
	 
  
						
				 | 
			
			
				
					Public BL   phaseContrastIndicator
				 | 
			
			
														
					 Details:
					
					
						
							| Alias: | 
							 | 
						 
						
							| Initial: | 
							 | 
						 
						
							| Stereotype:  | 
							 | 
						 
						
							| Ordered:  | 
							 | 
						 
						
							| Range:  | 
							 | 
						 
						
							| Transient:  | 
							False | 
						 
						
							| Derived:  | 
							False | 
						 
							
							| IsID:  | 
						False | 
						 
					 
					
					Map:DICOM=MR Pulse Sequence Module - Phase Contrast (0018,9014) 
						
	
		| 
			Notes:  
		 | 
		
			DEFINITION:<br/>Specifies whether this is a pulse sequence in which the flowing spins are velocity encoded in phase. <br/><br/>EXAMPLE(S):<br/><br/>OTHER NAME(S):<br/><br/>NOTE(S):<br/>
		 | 
	 
  
						
				 | 
			
			
				
					Public BL   timeOfFlightContrastIndicator
				 | 
			
			
														
					 Details:
					
					
						
							| Alias: | 
							 | 
						 
						
							| Initial: | 
							 | 
						 
						
							| Stereotype:  | 
							 | 
						 
						
							| Ordered:  | 
							 | 
						 
						
							| Range:  | 
							 | 
						 
						
							| Transient:  | 
							False | 
						 
						
							| Derived:  | 
							False | 
						 
							
							| IsID:  | 
						False | 
						 
					 
					
					Map:DICOM=MR Pulse Sequence Module - Time of Flight Contrast (0018,9015) 
						
	
		| 
			Notes:  
		 | 
		
			DEFINITION:<br/>Specifies whether contrast is created by the inflow of blood in the saturated plane. <br/><br/>EXAMPLE(S):<br/><br/>OTHER NAME(S):<br/><br/>NOTE(S):<br/>
		 | 
	 
  
						
				 | 
			
			
				
					Public CD   arterialSpinLabelingContrastCode
				 | 
			
			
														
					 Details:
					
					
						
							| Alias: | 
							 | 
						 
						
							| Initial: | 
							 | 
						 
						
							| Stereotype:  | 
							 | 
						 
						
							| Ordered:  | 
							 | 
						 
						
							| Range:  | 
							 | 
						 
						
							| Transient:  | 
							False | 
						 
						
							| Derived:  | 
							False | 
						 
							
							| IsID:  | 
						False | 
						 
					 
					
					Map:DICOM=MR Pulse Sequence Module - Arterial Spin Labeling Contrast (0018,9250) 
						
	
		| 
			Notes:  
		 | 
		
			DEFINITION:<br/>A coded value specifying how arterial water is used as a diffusable tracer. <br/><br/>EXAMPLE(S):<br/>CONTINUOUS - a single long low powered RF pulse <br/>PSEUDOCONTINUOUS - multiple short low powered RF pulses <br/>PULSED - a single short high powered RF pulse <br/><br/>OTHER NAME(S):<br/><br/>NOTE(S):<br/>
		 | 
	 
  
						
				 | 
			
			
				
					Public CD   steadyStatePulseSequenceCode
				 | 
			
			
														
					 Details:
					
					
						
							| Alias: | 
							 | 
						 
						
							| Initial: | 
							 | 
						 
						
							| Stereotype:  | 
							 | 
						 
						
							| Ordered:  | 
							 | 
						 
						
							| Range:  | 
							 | 
						 
						
							| Transient:  | 
							False | 
						 
						
							| Derived:  | 
							False | 
						 
							
							| IsID:  | 
						False | 
						 
					 
					
					Map:DICOM=MR Pulse Sequence Module - Steady State Pulse Sequence (0018,9017) 
						
	
		| 
			Notes:  
		 | 
		
			DEFINITION:<br/>A coded value specifying how residual transverse magnetization is maintained during the acquisition.<br/><br/>EXAMPLE(S):<br/>FREE_PRECESSION, TRANSVERSE, TIME_REVERSED, LONGITUDINAL, NONE<br/><br/>OTHER NAME(S):<br/><br/>NOTE(S):<br/>
		 | 
	 
  
						
				 | 
			
			
				
					Public BL   echoPlanarPulseSequenceIndicator
				 | 
			
			
														
					 Details:
					
					
						
							| Alias: | 
							 | 
						 
						
							| Initial: | 
							 | 
						 
						
							| Stereotype:  | 
							 | 
						 
						
							| Ordered:  | 
							 | 
						 
						
							| Range:  | 
							 | 
						 
						
							| Transient:  | 
							False | 
						 
						
							| Derived:  | 
							False | 
						 
							
							| IsID:  | 
						False | 
						 
					 
					
					Map:DICOM=MR Pulse Sequence Module - Echo Planar Pulse Sequence (0018,9018) 
						
	
		| 
			Notes:  
		 | 
		
			DEFINITION:<br/>Specifies whether multiple echos of different phase steps are acquired using rephasing gradients instead of repeated 180-degree pulses. <br/><br/>EXAMPLE(S):<br/><br/>OTHER NAME(S):<br/><br/>NOTE(S):<br/>
		 | 
	 
  
						
				 | 
			
			
				
					Public BL   saturationRecoveryIndicator
				 | 
			
			
														
					 Details:
					
					
						
							| Alias: | 
							 | 
						 
						
							| Initial: | 
							 | 
						 
						
							| Stereotype:  | 
							 | 
						 
						
							| Ordered:  | 
							 | 
						 
						
							| Range:  | 
							 | 
						 
						
							| Transient:  | 
							False | 
						 
						
							| Derived:  | 
							False | 
						 
							
							| IsID:  | 
						False | 
						 
					 
					
					Map:DICOM=MR Pulse Sequence Module - Saturation Recovery (0018,9024) 
						
	
		| 
			Notes:  
		 | 
		
			DEFINITION:<br/>Specifies whether a saturation recovery pulse sequence is used. <br/><br/>EXAMPLE(S):<br/><br/>OTHER NAME(S):<br/><br/>NOTE(S):<br/>
		 | 
	 
  
						
				 | 
			
			
				
					Public CD   spectrallySelectedSuppressionCode
				 | 
			
			
														
					 Details:
					
					
						
							| Alias: | 
							 | 
						 
						
							| Initial: | 
							 | 
						 
						
							| Stereotype:  | 
							 | 
						 
						
							| Ordered:  | 
							 | 
						 
						
							| Range:  | 
							 | 
						 
						
							| Transient:  | 
							False | 
						 
						
							| Derived:  | 
							False | 
						 
							
							| IsID:  | 
						False | 
						 
					 
					
					Map:DICOM=MR Pulse Sequence Module - Spectrally Selected Suppression (0018,9025) 
						
	
		| 
			Notes:  
		 | 
		
			DEFINITION:<br/>A coded value specifying the type of substance-specific signal suppression is  used. <br/><br/>EXAMPLE(S):<br/>FAT, WATER, FAT_AND_WATER, SILICON_GEL, NONE<br/><br/>OTHER NAME(S):<br/><br/>NOTE(S):<br/>
		 | 
	 
  
						
				 |